Component Characterization

HV-Test System for Capacitor Packages

Application Description

The system is used to characterize the leakage currents of capacitor packages. LXinstruments implemented a project-specific PCBA for the required HV switching. The measurement technology consists of Keithley source meters and USB based devices. The DUT adaptation with safety technology was realized in cooperation with ATX.

Customer Specific Software

The software for commissioning and self-test of the system was realized by LXinstruments in C#.

Industry
System Type
Employed Technology
  OTP...
LXI...
  VXI
Ethernet
  Image Processing / LED Evaluation
  Swithing of High DC Voltages and Currents
Switching of Voltages >300V
  DUT Programming (JTAG) etc.
  Embedded Controller by LX
Standard Software