Store for professionals (EU countries)
Give us a call: +49 (0) 7032-895 93 - 3

MV-GX7016

MV-GX7016
Price on request

Prices plus VAT plus shipping costs

The article is available.

  • MV-GX7016
Available downloads:
Model Marvin Test Solutions: MV-GX7016 GENASYS Switching Subsystem with SCOUT 6U Receiver... more
Product information "MV-GX7016"

Model Marvin Test Solutions: MV-GX7016
GENASYS Switching Subsystem with SCOUT 6U Receiver

  • 6U PXI chassis with integrated MAC Panel SCOUT receiver
  • 20 slot 6U PXI chassis supports GENASYS switching subsystem modules
  • Supports over 4000 multiplexed, hybrid pin connections
  • Supports up to 288 digital channels when integrated with a digital subsystem

A component of the GENASYS platform, the Marvin Test MV-GX7016 switching subsystem offers a new level of high performance, high density switching for board and system level functional test. Based on the 6U PXI architecture, the MV-GX7016 incorporates a modular switch matrix and multiplexer architecture which supports up to 4608 multiplexed, hybrid I/O pins. Up to 128 external resources can be connected to any of the test system’s receiver I/O pins via a high performance, internal 16 wire matrix bus. For digital test capability, the MV-GX7016’s switching subsystem can be connected to a digital subsystem such as Marvin Test Solutions’ MV-GX5960 digital subsystem, providing hybrid pin capability for each multiplexed I/O pin. Up to 288 digital channels are supported by the switching subsystem.

The MV-GX7016 chassis incorporates the MAC Panel 6U SCOUT receiver. The SCOUT receiver offers a reliable and high performance method to connect the switch modules to a mass interconnect receiver, minimizing the need for cable assemblies. The SCOUT receiver is a “pull-through” design, with each switch card providing a “cable-less” connection to the receiver connectors, - eliminating the need for cable harnesses and the associated reliability issues that come with cabled solutions. The result is a system interconnect design that is cost effective, reliable, and maintainable. The modular design of the SCOUT also allows for the use of a broad range of receiver connectors including high density, high current, and coaxial types. The 6U SCOUT receiver can accommodate up to 21 connector slots and over 8000 connections when fully populated.

Features

The Marvin Test MV-GX7016 is a 20-slot 6U PXI chassis that can accommodate up to 19 switching or instrument cards as well as a remote PXI bus interface such as the MXI-4. In addition to supporting all of the PXI-1 resources, the MV-GX7016’s PXI backplane provides an internal, high performance, 16 wire, analog bus via the backplane’s P5 connectors. Each of the GENASYS switching cards connects to this internal 16 wire bus, providing the ability to route signals from an external instrument to any of the receiver’s interface connections.

System power for the MV-GX7016 is provided by a 755 watt power supply. Forced-air cooling for the chassis is provided by a four (4) 79 CFM fans mounted under the card cage - providing positive airflow per the PXI specification. This configuration provides the optimum cooling for the chassis regardless of the type or number of instruments or switch cards used. Additional cooling is provided for the system power supply. This cooling configuration, in conjunction with air plenums within the chassis, provides airflow for all module slots per the PXI specification and requires no additional rack space for inlet or outlet air.

The MV-GX7016 Switching Subsystem chassis supports the monitoring of slot temperatures and system power supply voltages as well providing the ability to program or map each PXI trigger line from one PCI segment to another. In addition, the user can program the temperature monitoring function for specific warning and shutdown limits. All user specific setups can be stored in non-volatile memory as a user configuration and can be used as the default setup for normal chassis operation.

Scope of Delivery:

  • Marvin Test Solutions MV-GX7016: GENASYS Switching Subsystem with SCOUT 6U Receiver
  • Manual

Marvin Test Solutions ist ein amerikanischer Hersteller für PXI Instrumente und Software für Funktionstestsysteme und Halbleitertest.

  • Eine besondere Stärke von Marvin Test Solutions sind schnelle digitale Pattern-I/O Karten, FPGA- und SMU Karten im 3U und 6U PXI Formfaktor.
  • Neben Einzelkomponenten liefert Marvin auch vorkonfigurierte Funktionstestsysteme und Halbleitertestsysteme.
  • Mit der ATEasy Entwicklungsumgebung bietet Marvin Kunden, die eine eigene Testsoftware-Architektur realisieren wollen, einen leistungsfähigen Baukasten inkl. integrierter Sequenzerfunktionen.

LXinstruments vertreibt Produkte von Marvin Test Solutions in Deutschland, Österreich und der Schweiz.

Monitor holder for 19 “rack installation Monitor holder for 19 “rack installation
LXinstruments GmbH
LX-ZZ-0017-01

Price on request
Three-phase PDU | 1 x 250 A Input, 8 x 32 A Output, emergency stop Three-phase PDU | 1 x 250 A Input, 8 x 32 A...
LXinstruments GmbH
LX-PDU-250A-8X32A-NA

Price on request
Three-phase PDU | 1 x 125 A Input, 4 x 32 A Output, emergency stop Three-phase PDU | 1 x 125 A Input, 4 x 32 A...
LXinstruments GmbH
LX-PDU-125A-4X32A-NA

Content 1 piece(s)
€4,645.00 * €4,999.00 *
Three-phase PDU | 1 x 125 A Input, 2 x 63 A Output, emergency stop Three-phase PDU | 1 x 125 A Input, 2 x 63 A...
LXinstruments GmbH
LX-PDU-125A-2X63A-NA

Content 1 piece(s)
€4,445.00 * €4,800.00 *
Three-phase PDU | 3 x 63 A Input – Output, emergency stop Three-phase PDU | 3 x 63 A Input – Output,...
LXinstruments GmbH
LX-PDU-63A-3X63A-NA

Content 1 piece(s)
€4,195.00 * €4,500.00 *
Three-phase PDU | 1 x 63 A Input, 2 x 32 A Output, emergency stop Three-phase PDU | 1 x 63 A Input, 2 x 32 A...
LXinstruments GmbH
LX-PDU-63A-2X32A-NA

Content 1 piece(s)
€4,145.00 * €4,450.00 *
Three-phase PDU | 3 x 32 A Input-Output, emergency stop Three-phase PDU | 3 x 32 A Input-Output,...
LXinstruments GmbH
LX-PDU-32A-3X32A-NA

Content 1 piece(s)
€3,995.00 *
Three-phase PDU | 63 A, emergency stop Three-phase PDU | 63 A, emergency stop
LXinstruments GmbH
LX-PDU-03-63A-NA

Content 1 piece(s)
€3,795.00 *
Three-phase PDU | 32 A, emergency stop Three-phase PDU | 32 A, emergency stop
LXinstruments GmbH
LX-PDU-03-32A-NA

Content 1 piece(s)
€3,595.00 *
Three-phase PDU | 13 A, emergency stop Three-phase PDU | 13 A, emergency stop
LXinstruments GmbH
LX-PDU-03-13A-NA

Content 1 piece(s)
€3,295.00 *
Three-phase PDU | 25 A, emergency stop Three-phase PDU | 25 A, emergency stop
LXinstruments GmbH
LX-PDU-03-25A-NA

Content 1 piece(s)
€3,545.00 *
Single-phase PDU | 13 A, emergency stop Single-phase PDU | 13 A, emergency stop
LXinstruments GmbH
LX-PDU-01-13A-NA

Content 1 piece(s)
€2,995.00 *
Single-phase PDU | 13 A, 12 V, 24 V DC Single-phase PDU | 13 A, 12 V, 24 V DC
LXinstruments GmbH
LX-PDU-01-13A

Content 1 piece(s)
€2,545.00 *
2-in-1 High Voltage Test Enclosure | 10 kV large 2-in-1 High Voltage Test Enclosure | 10 kV large
LXinstruments GmbH
LX-HVE900EC

Price on request
2-in-1 High Voltage Test Enclosure | 10 kV small 2-in-1 High Voltage Test Enclosure | 10 kV small
LXinstruments GmbH
LX-HVE600EC

Price on request
Messsysteme | PG116:G180XI basiert Messsysteme | PG116:G180XI basiert
VTI Instruments
VTI-PXIe-Produkte

Price on request
Self-test application | Adapter, software Self-test application | Adapter, software
LXinstruments GmbH
OTP2-Modul-Nr210

Price on request
Magpie 2 | Database Evaluation Software Magpie 2 | Database Evaluation Software
LXinstruments GmbH
OTP2-Modul-Nr171

Price on request
Arbitrary generator | 2 channel, 20 MHz Arbitrary generator | 2 channel, 20 MHz
LXinstruments GmbH
OTP2-Modul-Nr131

Price on request
Arbitrary generator | 1 channel, 20 MHz Arbitrary generator | 1 channel, 20 MHz
LXinstruments GmbH
OTP2-Modul-Nr130

Price on request
PXI power supply | 1 channel, 40 W, 48 V, 2 A PXI power supply | 1 channel, 40 W, 48 V, 2 A
LXinstruments GmbH
OTP2-Modul-Nr197

Price on request
PXI RS232 interface | galvanic isolation PXI RS232 interface | galvanic isolation
LXinstruments GmbH
OTP2-Modul-Nr196

Price on request
Form A circuit card | 80 channel, 300 VDC, 2 A Form A circuit card | 80 channel, 300 VDC, 2 A
LXinstruments GmbH
OTP2-Modul-Nr195

Price on request
DUT matrix | 32 DUT matrix channels DUT matrix | 32 DUT matrix channels
LXinstruments GmbH
OTP2-Modul-Nr194

Price on request
Fixture Interface Module | 2 DUT matrices Fixture Interface Module | 2 DUT matrices
LXinstruments GmbH
OTP2-Modul-Nr193

Price on request
PXI Digitizer | 16 Bit, 20 MSa/s PXI Digitizer | 16 Bit, 20 MSa/s
LXinstruments GmbH
OTP2-Modul-Nr192

Price on request
PXI Oscilloscope | 2 channel, 250 Msa/s PXI Oscilloscope | 2 channel, 250 Msa/s
LXinstruments GmbH
OTP2-Modul-Nr191

Price on request
Arbitrary function generator | 14 bit, 100 Msa/s Arbitrary function generator | 14 bit, 100 Msa/s
LXinstruments GmbH
OTP2-Modul-Nr190

Price on request
RF Multiplexer | 3 GHz, 4 to 1 RF Multiplexer | 3 GHz, 4 to 1
LXinstruments GmbH
OTP2-Modul-Nr189

Price on request
Isolated D/A converter | 8 channel, 250 kSa/s Isolated D/A converter | 8 channel, 250 kSa/s
LXinstruments GmbH
OTP2-Modul-Nr187

Price on request
Isol. Digital I/O | 60 VDC, 150 mA Isol. Digital I/O | 60 VDC, 150 mA
LXinstruments GmbH
OTP2-Modul-Nr186

Price on request
PXI embedded controller | I5, Dual Core, Win 7 PXI embedded controller | I5, Dual Core, Win 7
LXinstruments GmbH
OTP2-Modul-Nr184

Price on request
PCIe card | MX3 copper interface PCIe card | MX3 copper interface
LXinstruments GmbH
OTP2-Modul-Nr183

Price on request
PXI infrastructure | PXI mainframe + components PXI infrastructure | PXI mainframe + components
LXinstruments GmbH
OTP2-Modul-Nr182

Price on request
PXI enclosure | for standalone operation PXI enclosure | for standalone operation
LXinstruments GmbH
OTP2-Modul-Nr181

Price on request
PXI rack-mounting | material for installation PXI rack-mounting | material for installation
LXinstruments GmbH
OTP2-Modul-Nr180

Price on request
CAN/LIN interfaces | 2 channel, PCIe CAN/LIN interfaces | 2 channel, PCIe
LXinstruments GmbH
OTP2-Modul-Nr053

Price on request
Pneumatic subsystem | Ventilation, maintenance Pneumatic subsystem | Ventilation, maintenance
LXinstruments GmbH
OTP2-Modul-Nr050

Price on request
Midirack | installed peripherals Midirack | installed peripherals
LXinstruments GmbH
OTP2-Modul-Nr044

Price on request
Rack | Touch display on swivel arm Rack | Touch display on swivel arm
LXinstruments GmbH
OTP2-Modul-Nr042

Price on request
Viewed